 Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
Typical units
FEATURES
12V/15V and 3.3V/5V outputs 10-18V, 18-36V or 36-75V inputs Up to 22.5 Watts total output power with overtemperature shutdown To 87% efficiency; 80-100mV Ripple and Noise 1" x 2" x 0.5" encapsulated package 1500Vdc isolation for both outputs Designed to meet UL 60950-1, CSA-C22.2 No. 60950-1, EN60950-1 safety approvals Extensive self-protection with short circuit shutdown Output overvoltage and overcurrent protection Input under and overvoltage shutdown Ideal for mixed analog/digital systems
Packaged in 1" x 2" encapsulated modules, the TWR 22W series DC/DC converters offer three outputs arranged as a unipolar low voltage supply and a higher voltage bipolar output pair. The unipolar section supplies either +3.3V at 4A maximum or +5V at 3A maximum. The bipolar outputs are either 12Vdc at 300mA maximum or 15Vdc at 250mA and are ideal for op amps, linear or analog circuits. A single TWR converter can power applications with combined analog and digital circuits such as a CPU-controlled voice switch, embedded telephone modem or analytical instruments. The input section is fully isolated from the outputs up to 1500Vdc minimum using Basic insulation. Three wide input ranges are available including 10-18V (12Vdc nominal), 18-36V (24Vdc nomimal) or 36-75V (48Vdc nominal). Peak-to-peak output ripple/noise is typically 80-100mV at full load. Efficiencies range up to 87%. The TWR 22W series outputs will limit their current if driven to overload and may be short circuited indefinitely without damage. The inputs will shut down if input voltage is either over or under limits or has reversed input voltage. These converters will operate at higher temperatures with adequate airflow. The unipolar output features line and load regulation of 1%. Excellent dynamic response assures transient load change settling within 100 microseconds. Other convenience features include a remote On/Off control to turn the outputs on via digital logic, CPU bit, control transistor or a relay. Fabrication uses DATEL's advanced surface mount automated pick-and-place assembly and computer-controlled parameter testing. All TWR 22W series are designed to meet safety requirements in UL, EN60950-1 and CSA-C22.2 No.60950-1.
Figure 1. Simplified block diagram
For full details go to www.murata-ps.com/rohs
Typical topography is shown.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 1 of 9
Triple Output/TWR Models
Performance Specifications and Ordering Guide
Output
Isolated, High Reliability 1" x 2" DC/DC Converters
Input
R/N (mvp-p) Model TWR-3.3/4-12/300-D12-C TWR-3.3/4-12/300-D24-C TWR-3.3/4-12/300-D48N-C TWR-3.3/4-15/250-D12-C TWR-3.3/4-15/250-D24-C TWR-3.3/4-15/250-D48N-C TWR-5/3-12/300-D12-C TWR-5/3-12/300-D24-C TWR-5/3-12/300-D48N-C TWR-5/3-15/250-D12-C TWR-5/3-15/250-D24-C TWR-5/3-15/250-D48N-C VOUT Volts 3.3 12 3.3 12 3.3 12 3.3 15 3.3 15 3.3 15 5 12 5 12 5 12 5 15 5 15 5 15 IOUT Amps 4 0.3 4 0.3 4 0.3 4 0.25 4 0.25 4 0.25 3 0.3 3 0.3 3 0.3 3 0.25 3 0.25 3 0.25 Typ. 40 70 Max. 60 150
Regulation (Max.) Line 0.05% 0.35% Load 0.4% 2.5% VIN Nom. (Volts) 12 Range (Volts) 9-18
Input Current No Load (mA) 170 Full Load (Amps) 2.00
Efficiency Min. 82% Typ. 85%
Packag (Case/ Pinout) C39/P61 C39/P61
Please contact Murata Power Solutions for further information.
C39/P61 C39/P61
80 100 80 100 80 100 80 100 80 100 40 45 40 45 65 45
100 150 100 150 100 150 100 150 100 150 75 65 75 65 100 60
1% 5% 1% 5% 1% 5% 1% 5% 1% 5% 0.05% 0.5% 0.4% 0.4% 0.05% 0.4%
1% 5% 1% 5% 1% 5% 1% 5% 1% 5% 0.2% 4% 0.2% 4% 0.3% 4%
24 48 12 24 48 12 24 48
18-36 36-75 9-18 18-36 36-75 9-18 18-36 36-75
25 25 120 90 25 170 80 45
1.00 0.50 2.20 1.08 0.53 2.26 1.09 0.54
83% 85% 81.5% 83% 85% 81% 83% 85%
86% 87% 84% 86% 87% 83% 86% 87.5%
C39/P61 C39/P61 C39/P61 C39/P61 C39/P61 C39/P61 C39/P61 C39/P61
T WR - 5 / 3 - 12 / 300
Output Configuration Wide Range Input Nominal Primary Output Voltage Maximum Primary Output Current
D48 N - C
RoHS-6 Hazardous Substance Compliance On/Off Control Polarity Input Voltage Range
See page 9 for complete Part Number Structure and Ordering Information
Maximum Auxiliary Output Current Nominal Auxiliary Output Voltage
MECHANICAL SPECIFICATIONS
2.00 (50.8) PLASTIC CASE 0.49 (12.5) STANDOFF 0.020 (0.5)
0.20 MIN (5.1)
0.040 0.002 DIA. (1.016 0.051) 1.800 (45.72) 0.10 (2.5) 4 1 2 5 6 7 BOTTOM VIEW
0.200 (5.08)
I/O Connections Pin Function P61 1 +Input 2 -Input 3 On/Off Control 4 +12V/15V Output 5 -12V/15V Output 6 Common 7 +3.3/5V Output Alternate pin length and/or other output voltages are available under special quantity order.
Dimensions are in inches (mm shown for ref. only).
Third Angle Projection
0.300 (7.62)
0.800 0.600 (20.32) (15.24)
1.00 (25.4)
Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 Components are shown for reference only.
3
0.10 (2.5)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 2 of 9
Triple Output/TWR Models
Performance/Functional Specifications
Typical @ TA = +25C under nominal line voltage, nominal output voltage, natural air convection, external caps and full-load conditions unless noted. Input
Isolated, High Reliability 1" x 2" DC/DC Converters
Short Circuit Duration (no damage) Overvoltage Protection: 3.3V or 5V Output 12V or 15V Outputs Continuous, output shorted to ground 3.8Vdc minimum, 4.2Vdc maximum 30Vdc maximum Method: magnetic feedback
Dynamic Characteristics
Input Voltage Range Start-Up Threshold: 12V Models 24V Models 48V Models Undervoltage Shutdown: 12V Models 24V Models 48V Models Overvoltage Shutdown: 12V Models 24V Models 48V Models Reflected (Back) Ripple Current Input Current: Full Load Conditions No Load VIN = nominal 12V and 24V Models 48V Models Low-Line Voltage (VIN = VMIN, full load) Remote On/Off Control Positive Logic (no model suffix) Current Negative Logic (N model suffix) Current
See Ordering Guide 9V minimum, 9.5V typical 16.5V minimum, 17V typical 34V minimum, 35V typical 8V minimum, 8.5V typical 16V minimum, 16.5V typical 32.5V minimum, 34.5V typical 20V typical, 21V maximum 38V typical, 40V maximum 78.5V typical, 81V maximum 12mA typical, 20mAp-p maximum See Ordering Guide 25mA typical, 50mA maximum 170mA typical, 200mA maximum TBD Off = ground pin to +1.2V maximum On = open pin to +VIN maximum 2mA maximum On = ground pin to +1.2V maximum Off = open pin to +VIN maximum 18mA maximum
Output
Dynamic Load Response (50-100% loadstep) 3.3V or 5V Output 150sec to 1.5% of final value 12V or 15V Outputs 150sec to 10% of final value Start-Up Time VIN to VOUT regulated Switching Frequency TBD msec for VOUT = nominal 330kHz 20kHz
Environmental
Calculated MTBF Operating Temperature: (Ambient) No Derating (Natural convection) With Derating Operating Case Temperature Storage Temperature Thermal Protection/Shutdown Density Altitude Relative Humidity
TBD -40 to +65C See Derating Curves -40 to +100C maximum -40 to +120C +110C minimum to 120C maximum 0 to 10,000 feet 10% to 90%, non-condensing
Physical
Dimensions Case and Header Material Pin Dimensions/Material alloy with nickel underplate.
See Mechanical Specifications Black Diallyl Phthalate plastic 0.04" (1.016mm) dia. Gold-plated copper
VOUT Range VOUT Accuracy: 3.3V or 5V Output 12V or 15V Outputs Temperature Coefficient Minimum Loading: 3.3V or 5V Output 12V or 15V Outputs Ripple/Noise (20MHz BW) Line/Load Regulation Efficiency Maximum Capacitive Loading: 3.3V or 5V Output 12V or 15V Outputs Isolation: Input to Output Voltage Resistance Capacitance Isolation Safety Rating Current Limit Inception: (98% of VOUT) 3.3V Output 5V Output 12V Outputs 15V Outputs Short-Circuit Detection: 3.3V or 5V Output 12V or 15V Outputs Short-Circuit Potection Method Short-Circuit Current: 3.3V or 5V Output 12V or 15V Outputs
See Ordering Guide 1% of VNOM 10% of VNOM (See Technical Notes) 0.02% of VOUT range/C See Technical Notes No minimum load 20% minimum of nominal output current, balanced load See Ordering Guide See Ordering Guide & Technical Notes See Ordering Guide TBD TBD 1500Vdc minimum 100M 470pF Functional insulation 5 Amps minimum, 6.2 Amps maximum 4 Amps minimum, 5.2 Amps maximum 0.36 Amps minimum, 1 Amp maximum 0.5 Amps minimum, 1.2 Amps maximum Magnetic feedback Magnetic feedback plus voltage clamp Current limiting with hiccup autorestore. Remove overload for recovery. 2 Amps maximum 1 Amp maximum
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 3 of 9
Weight Electromagnetic Interference Safety TBD
TBD UL/cUL 60950-1 CSA-C22.2 No.234 IEC/EN 60950-1
All models are tested/specified with two external 0.047F output capacitors. These capacitors are necessary to accommodate our test equipment and may not be required to achieve specified performance in your applications. All models are stable and regulate within spec under no-load conditions. Input Reflected Ripple Current is tested/specified over a 20MHz bandwidth. Input filtering is CIN = 33F, 100V tantalum; CBUS = 220F, 100V electrolytic; LBUS = 12H. See Technical Notes. For consistent operation, the instantaneous input voltage for full output load must not go below the low shutdown voltage AT ALL TIMES. Beware of excessive voltage drop from long input wiring. For reliable startup, be sure to apply input power promptly and fully as a step function. Mean Time Before Failure is calculated using the Telcordia (Belcore) SR-332 Method 1, Case 3, ground fixed conditions, TCASE = +25C, full load, natural air convection. The On/Off Control may be driven with external logic or the application of appropriate voltages (referenced to Common). The On/Off Control input should use either an open collector/open drain transistor or logic gate which does not exceed +VIN. The On/Off Control may be supplied with with negative logic (LO = on, HI = off) using the "N" model suffix. Maximum Power Derating curves indicate an average current at nominal input voltage. At higher temperatures and/or lower airflow, the DC/DC converter will tolerate brief full current outputs if the total RMS current over time does not exceed the derating curve. All models are fully operational and meet published specifications, including cold start at -40C. Output noise may be further reduced by adding an external filter. See I/O Filtering and Noise Reduction. The outputs share a common isolated return. The two output sections are not isolated from each other. Regulation specifications describe the deviation as the line input voltage or output load current is varied from a nominal midpoint value to either extreme. The outputs will not accept appreciable reverse current without possible damage.
www.murata-ps.com
Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
Absolute Maximum Ratings
Input Undervoltage Shutdown and Start-Up Threshold Under normal start-up conditions, devices will not begin to regulate until the ramping-up input voltage exceeds the Start-Up Threshold Voltage. Once operating, devices will not turn off until the instantaneous input voltage drops below the Undervoltage Shutdown limit. Subsequent restart will not occur until the input is brought back up to the Start-Up Threshold. This built-in hysteresis avoids any unstable on/off situations occurring at a single input voltage. However, you should be aware that poorly regulated input sources and/or higher input impedance sources (including long power leads) which have outputs near these voltages may cause cycling of the converter outputs. Ripple Current and Output Noise All TWR converters are tested and specified for input reflected ripple current (also called Back Ripple Current) and output noise using specified filter components and test circuit layout as shown in the figures below. Input capacitors must be selected for low ESR, high AC current-carrying capability at the converter's switching frequency and adequate bulk capacitance. The switching nature of DC/DC converters requires this low AC impedance to absorb the current pulses reflected back from the converter's input.
Input Voltage: Continuous or transient 12V Models 24V Models 48V Models On/Off Control (Pin 1) Input Reverse-Polarity Protection Output Overvoltage Protection Output Current
-0.3V minimum or +18V maximum -0.3V minimum or +36V maximum -0.3V minimum or +75V maximum -0.3V minimum or +VIN maximum See Fuse section VOUT +20% maximum Current limited. Devices can withstand sustained output short circuits without damage. -40 to +120C +300C
Storage Temperature Lead Temperature (soldering 10 sec. max.)
These are stress ratings. Exposure of devices to any of these conditions may adversely affect long-term reliability. Proper operation under conditions other than those listed in the Performance/Functional Specifications Table is not implied.
TECHNICAL
NOTES
Load Dependency and Regulation The high voltage bipolar output section derives its regulation as a slave to the low voltage unipolar output. Be aware that large load changes on the unipolar section will change the voltage somewhat on the bipolar section. To retain proper regulation, the bipolar voltage section must have a minimum load of at least 10% of rated full output. With this minimal load (or greater), the high voltage bipolar section will meet all its regulation specifications. If there is no load, the output voltage may exceed the regulation somewhat. Input Fusing Certain applications and/or safety agencies require fuses at the inputs of power conversion components. Fuses should also be used if there is the possibility of sustained, non-current limited reverse input polarity. DATEL recommends slow-blow type fuses approximately twice the maximum input current at nominal input voltage but no greater than 5 Amps. Install these fuses in the high side (ungrounded input) power lead to the converter. Input Voltage 12 Volts 24 Volts 48 Volts Input Source Impedance The external source supplying input power must have low AC impedance. Failure to insure adequate low AC impedance may cause stability problems, increased output noise, oscillation, poor settling and aborted start-up. The converter's built-in front end filtering will be sufficient in most applications. However, if additional AC impedance reduction is needed, consider adding an external capacitor across the input terminals mounted close to the converter. The capacitor should have low internal Equivalent Series Resistance (ESR) and low inductance. Often, two or more capacitors are used in parallel. A ceramic capacitor gives very low AC impedance while a parallel electrolytic capacitor offers improved energy storage. Fuse Value 4 Amps 2 Amps 1 Amp
Figure 2. Measuring Input Ripple Current
Output Overcurrent Detection Overloading the power converter's output for extended periods (but not a short circuit) at high ambient temperatures may overheat the output components and possibly lead to component failure. Brief moderate overcurrent operation (such as charging up reasonably-sized external bypass capacitors when first starting) will not cause problems. The TWR series include current limiting to avoid heat damage. However, you should remove a sustained overcurrent condition promptly as soon as it is detected. Combinations of low airflow and/or high ambient temperature for extended periods may cause overheating even though current limiting is in place. Current Return Paths Make sure to use adequately sized conductors between the output load and the Common connection. Avoid simply connecting high current returns only through the ground plane unless there is adequate copper thickness. Also, route the input and output circuits directly to the Common pins. Failure to observe proper wiring may cause instability, poor regulation, increased noise, aborted start-up or other undefined operation.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 4 of 9
Triple Output/TWR Models
Safety Considerations The TWR's must be installed with consideration for any local safety, certification or regulatory requirements. These vary widely but generally are concerned with properly sized conductors, adequate clearance between higher voltage circuits, life testing, thermal stress analysis of components and flammability of components. Contact DATEL if you need further advice on these topics. Remote On/Off Control The TWR models include an input pin which can turn on or shut off the converter by remote signal. For positive logic models (no model number suffix), if this pin is left open, the converter will always be enabled as long as proper input power is present. On/Off signal currents are referred to the Input Common pin on the converter. There is a short time delay of several milliseconds (see the specifications) for turn on, assuming there is no significant external output capacitance. The On/Off Control may also be supplied with negative logic (LO = on, HI = off) using the "N" model number suffix. Here again, leaving the pin open on either model will enable the converter. Positive logic models must have this control pin pulled down for shutoff. Negative logic models must pull up this control pin for shutoff. Dynamic control of this On/Off input is best done with either a mechanical relay (ground the pin to turn it off), solid state relay (SSR), an open collector or open drain transistor, CPU bit or a logic gate. The pull down current is 18mA max. Observe the voltage limits listed in the specifications for proper operation. Suggested circuits are shown below.
Isolated, High Reliability 1" x 2" DC/DC Converters
Isolation Considerations These converters use both transformer and optical coupling to isolate the inputs from the outputs. Ideal "floating" isolation implies ZERO CURRENT flowing between the two Common return sections of the input and output up to the working isolation voltage limit. Real-world isolation on this converter includes both an AC current path (through some small coupling capacitance) and some DC leakage current between the two ground systems. To avoid difficulties in your application, be sure that there are not wideband, high amplitude AC difference voltages between the two ground systems. In addition, ground difference voltages applied by your external circuits which exceed the isolation voltage, even momentarily, may damage the converter's isolation barrier. This can either destroy the converter or instantly render it non-isolated. Current Limiting and Short Circuit Condition As the output load increases above its maximum rated value, the converter will enter current limiting mode. The output voltage will decrease and the converter will essentially deliver constant power. This is commonly called power limiting. If the current continues to increase, the converter will enter short circuit operation and the PWM controller will shut down. Following a time-out period, the converter will automatically attempt to restart. If the short circuit is detected again, the converter will shut down and the cycle will repeat. This operation is called hiccup autorecovery. Please be aware that excessive external output capacitance may interfere with the hiccup autorestart. Output Filtering and Noise Reduction All switching DC/DC converters produce wideband output noise which radiates both through the wiring (conducted emission) and is broadcast into the air (radiated emission). This output noise may be attenuated by adding a small amount of capacitance in parallel with the output terminals. Please refer to the maximum output capacitance in the Specifications. The amount of capacitance to add depends on the placement of the cap (near the converter versus near the load), the distance from the converter to the load (and resulting series inductance), the topology and locations of load elements if there are multiple parallel loads and the nature of the loads. For switching loads such as CPU's and logic, this last item recommends that small bypass capacitors be placed directly at the load. Very high clock speeds suggest smaller caps unless the instantaneous current changes are high. If the load is a precision high-gain linear section, additional filtering and shielding may be needed. Many applications will need no additional capacitance. However, if more capacitance is indicated, observe these factors: 1. Understand the noise-reduction objective. Are you improving the switching threshold of digital logic to reduce errors? (This may need only a small amount of extra capacitance). Or do you need very low noise for a precision linear "front end"? 2. Use just enough capacitance to achieve your objective. Additional capacitance trades off increasing instability (actually adding noise rather than reducing it), poor settling response, possible ringing or outright oscillation by the converter. Excessive capacitance may also disable the hiccup autorestart. Do not exceed the maximum output capacitance specification.
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 5 of 9
Figure 3. On/Off Control With An External CMOS Gate
Figure 4. On/Off Control With An External Transistor
www.murata-ps.com
Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
3. Any series inductance considerably complicates the added capacitance therefore try to reduce the inductance seen at the converter's output. You may need to add BOTH a cap at the converter end and at the load (effectively creating a Pi filter) for the express purpose of reducing the phase angle which is seen by the converter's output loop controller. This tends to hide (decouple) the inductance from the controller. Make sure your power conductors are adequate for the current and reduce the distance to the load as much as possible. Very low noise applications may require more than one series inductor plus parallel caps. 4. Oscillation or instabilility can occur at several frequencies. For this reason, you may need both a large electrolytic or tantalum cap (carrying most of the capacitance) and a small wideband parallel ceramic cap (with low internal series inductance). Always remember that inside real world capacitors are distributed trace inductance (ESL) and series resistance (ESR). Make sure the input AC impedance is very low before trying to improve the output. 5. It is challenging to offer a complete set of simple equations in reasonable closed form for the added output capacitance. Part of the difficulty is accurately modeling your load environment. Therefore your best success may be a combination of previous experience and empirical approximation. Maximum Current and Temperature Derating Curves The curves shown below indicate the maximum average output current available versus the ambient temperature and airflow. All curves are done approximately at sea level and you should leave an additional margin for higher altitude operation and possible fan failure. (Remember that fans are less efficient at higher altitudes). These curves are an average - current may be greater than these values for brief periods as long as the average value is not exceeded. The "natural convection" area of the curve is that portion where selfheating causes a small induced convective airflow around the converter without further mechanical forced airflow from a fan. Natural convection assumes that the converter is mounted with some spacing to adjacent components and there are no nearby high temperature parts. Note that such self-heating will produce an airflow of typically 25 Linear Feet per Minute (LFM) without a fan. Heat is removed both through the mounting pins and the surface of the converter. Many systems include fans however it is not always easy to measure the airflow adjacent to the DC/DC converter. Simply using the cubic feet per minute (CFM) rating of the fan is not always helpful since it must be matched to the volume of the enclosure, the outside ambient temperature, board spacing, the intake area and total internal power dissipation. Most PWM controllers, including those on the TWR's, will tolerate operation up to about +100 degrees Celsius. If in doubt, attach a thermal sensor to the package near the output components and measure the surface temperature after allowing a proper warm-up period. Remember that the temperature inside the output transistors at full power will be higher than the surface temperature therefore do not exceed operation past approximately +100 deg. C on the surface. As a rough indication, any circuit which you cannot touch briefly with your finger warrants further investigation. It is probably more important in your system that all heat is periodically removed rather than having very high airflow. Consider having the total enclosure completely recycled at least several times a minute. Failure to remove the heat causes heat buildup inside your system and even a small fan (relative to the heat load) is quite effective. A very rough guide for typical enclosures is one cubic foot per minute of exhausted airflow per 100 Watts of internal heat dissipation.
Efficiency Curves These curves indicate the ratio of output power divided by input power at various input voltages and output currents times 100%. All curves are measured at +25C ambient temperature and adequate airflow.
Typical Performance Curves for TWR Series
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 6 of 9
Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
Typical Performance Curves for TWR Series
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 7 of 9
Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
Typical Performance Curves for TWR Series
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 8 of 9
Triple Output/TWR Models
Isolated, High Reliability 1" x 2" DC/DC Converters
PART
NUMBER
STRUCTURE
T WR - 5 / 3 - 12 / 300 - D48 N - C
Output Configuration: T = Triple Wide Range Input Nominal Primary Output Voltage (+3.3 or +5 Volts) Maximum Primary Output Current in Amps RoHS-6 Hazardous Substance Compliance On/Off Control Polarity Blank = Positive Logic N = Negative Logic Input Voltage Range: D12 = 10-18 Volts (12V nominal) D24 = 18-36 Volts (24V nominal) D48 = 36-75 Volts (48V nominal) Maximum Auxiliary Output Currents in mA from each output Nominal Auxiliary Output Voltages (12 or 15 Volts) Note: Some model number combinations may not be available. Contact Murata Power Solutions.
USA: UK: France: Japan:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Website: www.murata-ps.jp Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com
Canada: Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 REGISTERED
06/12/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2008 Murata Power Solutions, Inc.
Germany: Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com
China:
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MDC_TWR22.B02 Page 9 of 9


▲Up To Search▲   

 
Price & Availability of TWR-334-12300-D12-C

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X